Arq. bras. oftalmol ; 86(6): e2021, 2023. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1520196

RESUMO

ABSTRACT Purpose: The purpose of this study was to compare the white-to-white distance measurements of two devices (IOL Master 500 and Atlas corneal topographer) commonly used in clinical practice to determine if they were interchangeable. Providing information on instrument interchangeability could eliminate several unnecessary tests and consequently reduce the economic burden for the patient and society. Methods: In this prospective, comparative case series, the white-to-white distance was measured by independent examiners using the Atlas topographer (Carl Zeiss Meditec) and the IOL Master 500 (Carl Zeiss Meditec). One eye each of 184 patients was tested. Statistical analyses were performed using a paired t-test, Pearson correlation analysis, and Bland-Altman analysis to compare the measurement methods. Results: The mean white-to-white distance measurements with the Atlas topographer and the IOL Master 500 were 12.20 ± 0.44 mm and 12.12 ± 0.41 mm, respectively (p<0.001). The mean white-to-white difference between the two devices was 0.07 mm (95% confidence interval of mean difference: 0.04-0.11 mm). The Pearson correlation coefficient between the two devices was 0.85 (p<0.0001). The 95% limits of agreement between the two devices were -0.38 mm to 0.53 mm. Conclusions: The Atlas topographer and IOL Master 500 can be used interchangeably with respect to white-to-white distance measurements, as the range of differences is unlikely to affect clinical practice and decision making.


RESUMO Objetivo: O objetivo deste estudo é comparar as medições de diâmetro corneano de dois dispositivos normalmente utilizados na prática clínica (IOL Master 500 e Atlas topógrafo corneal) para ver se são permutáveis. O fornecimento de informações sobre a permutabilidade de instrumentos poderia eliminar vários testes desnecessários e, consequentemente, reduzir a carga econômica para o paciente e para a sociedade. Métodos: Nesta série de casos prospectivos e comparativos, a distância do diâmetro corneano foi medida por examinadores independentes utilizando o Topógrafo Atlas (Carl Zeiss Meditec) e o IOL Master 500 (Carl Zeiss Meditec), em um olho de 184 pacientes. A análise estatística foi realizada utilizando o teste t pareado, a correlação Pearson e a análise Bland-Altman para comparar os métodos de medição. Resultados: As medições médias da distância do diâmetro corneano com o topógrafo Atlas e o IOL Master 500 foram de 12,20 ± 0,44 mm e 12,12 ± 0,41 mm, respectivamente (p<0,001). A diferença média de WTW entre os dois dispositivos foi de 0,07 mm (intervalo de confiança de 95% da diferença média: 0,04 - 0,11 mm). O coeficiente de correlação Pearson entre os dois dispositivos foi de 0,85, p<0,0001. Os limites de concordância de 95% entre os dois dispositivos foram de -0,38 mm a 0,53 mm. Conclusões: O Atlas topographer e o IOL Master 500 podem ser utilizados permutavelmente em relação à medição do diâmetro corneano, uma vez que a gama de diferenças encontradas é pouco susceptível de afetar a prática clínica e a tomada de decisões.

2.
Arq. bras. oftalmol ; 84(3): 271-274, May-June 2021. graf
Artigo em Inglês | LILACS | ID: biblio-1248964

RESUMO

ABSTRACT This study aimed to analyze the anterior lens capsule specimens from both eyes of a patient with systemic sclerosis and compare them to the eyes of a control patient. No significant differences between systemic sclerosis and control eyes were observed in the results from the hematoxylin-eosin and picrosirius staining. In the samples obtained from both systemic sclerosis and control eyes, there were expressions of caspase, a molecule expressed in cell death by apoptosis. Heparanase was overexpressed in the systemic sclerosis sample compared to the control sample. Therefore, the anterior lens capsule of the patient with systemic sclerosis is probably affected by the disease since it showed marked expression of heparanase 1.(AU)


RESUMO Analisamos as amostras das cápsulas anteriores do cristalino de uma paciente com esclerose sistêmica e comparamos com as de um paciente controle. Não foram observadas diferenças significativas entre esclerose sistêmica e controle nos resultados da coloração com hematoxilina-eosina e picrosirius. Nas amostras obtidas da esclerose sistêmica e do controle, obtivemos expressão de caspase, uma molécula expressa na morte celular por apoptose. A heparinase foi expressa de forma mais marcante na amostra de esclerose sistêmica quando comparada ao controle. Portanto, a cápsula anterior do cristalino da paciente com esclerose sistêmica provavelmente foi afetada pela doença, uma vez que mostrou expressão aumentada de heparinase 1.(AU)


Assuntos
Humanos , Escleroderma Sistêmico/fisiopatologia , Heparina Liase/administração & dosagem , Hematoxilina , Cápsula do Cristalino/anatomia & histologia
3.
Arq. bras. oftalmol ; 82(5): 377-380, Sept.-Oct. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1019430

RESUMO

ABSTRACT Purpose: To assess the frequency of corneal astigmatism before cataract surgery in a Brazilian sample. Methods: This clinic-based cross-sectional study was conducted at the Bonsucesso Federal Hospital, Rio de Janeiro, Brazil. Charts of patients who underwent cataract surgery over a two-year period were retrospectively reviewed, and preoperative keratometric measurements were collected and analyzed. Results: A total of 1707 eyes of 1045 patients were enrolled. The corneal astigmatism was less than 1.0 D in 971 eyes (56.9%), 1.0-1.99 D in 496 eyes (29.1%), 2.0-2.99 D in 157 eyes (9.2%), and more than 3.0 D in 83 eyes (4.9%). The mean corneal astigmatism was 0.92 ± (SD) 0.96 D (range 0 - 10.25 D). Conclusion: Over 40% of the patients undergoing cataract surgery enrolled in this study had more than 1.0 D of corneal astigmatism and may benefit from the use of toric intraocular lenses. These data can be useful for planning to make this technology available for patients.


RESUMO Objetivo: Avaliar a prevalência do astigmatismo corneano antes da cirurgia de catarata em pacientes brasileiros. Métodos: Este estudo transversal de base clínica foi realizado no Hospital Federal de Bonsucesso, Rio de Janeiro, Brasil. Os prontuários de pacientes submetidos à cirurgia de catarata durante um período de dois anos foram revisados retrospectivamente, e as medidas ceratométricas pré-operatórias foram coletadas e analisadas. Resultados: Um total de 1.707 olhos de 1045 pacientes foram incluídos. O astigmatismo corneano foi menor que 1,0 D em 971 olhos (56,9%), 1,0-1,99 D em 496 olhos (29,1%), 2,0-2,99 D em 157 olhos (9,2%) e mais de 3,0 D em 83 olhos (4,9%). A média do astigmatismo corneano foi de 0,92 ± (SD) 0,96 D (intervalo 0-10,25 D). Conclusão: Mais de 40% dos pacientes estudados submetidos à cirurgia de catarata incluídos neste estudo tinham mais de 1,0 D de astigmatismo corneano e podem se beneficiar do uso de lentes intraoculares tóricas. Esses dados podem ser úteis no planejar a disponibilização dessa tecnologia para os pacientes.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Astigmatismo/epidemiologia , Catarata/complicações , Extração de Catarata , Doenças da Córnea/epidemiologia , Brasil/epidemiologia , Prevalência , Estudos Transversais , Estudos Retrospectivos , Córnea/fisiopatologia , Hospitais Públicos
4.
Arq. bras. oftalmol ; 80(4): 238-241, July-Aug. 2017. tab
Artigo em Inglês | LILACS | ID: biblio-888125

RESUMO

ABSTRACT Purpose: To study the technique of eye drop instillation in glaucoma patients and identify independent factors that may influence their performance. Methods: In this cross-sectional study, 71 consecutive patients with glaucoma or ocular hypertension, self-administering topical anti-glaucoma medications for ≥6 months were evaluated. All patients instilled a tear substitute into the eye with the worst eyesight using the technique normally used at home. The following parameters were evaluated: age, number of years receiving treatment with ocular hypotensive eye drops, time spent to instill the first drop, number of drops instilled, correct location of the eye drops, contact of the bottle with the eye, closing of the eyelids or occlusion of the tear punctum, and asepsis of the hands. Results: The mean age of the patients was 66 ± 10.8 years, and patients were on ocular hypotensive drugs for 11.3 ± 7.3 (range, 2-35) years. Only 28% of the patients were able to correctly instill the eye drops (squeeze out 1 drop and instill it into the conjunctival sac without bottle tip contact). Touching the tip of the bottle to the globe or periocular tissue occurred in 62% of the patients. In 49% of the patients, the eye drops fell on the eyelids or cheek. Two or more drops were squeezed by 27% of the patients. Conclusions: The majority of glaucoma patients were unable to correctly instill eye drops. Age was an independent factor associated with eye drop instillation performance.


RESUMO Objetivo: Avaliar a técnica de instilação de colírio em portadores de glaucoma e identificar fatores independentes que pode influenciar o desempenho. Métodos: Neste estudo transversal 71 pacientes consecutivos com glaucoma ou hipertensão ocular que auto instilam seus colírios há pelo menos 6 meses, foram avaliados. Todos os pacientes instilaram um colírio lubrificante no olho de pior visão utilizando a mesma técnica de instilação de colírio que utilizam rotineiramente em casa. Foram avaliados parâmetros como: idade, número de anos em tratamento com colírios hipotensores oculares, tempo gasto para instilação da primeira gota, número de gotas instiladas, localização correta do colírio, contato do frasco com o olho, fechamento de pálpebras ou oclusão do ponto lacrimal e assepsia das mãos. Resultados: A idade média dos pacientes foi de 66 ± 10,8 anos. Os pacientes esta vam em tratamento com colírios hipotensores oculares por, em média, 11,3 ± 7,3 anos (variando de 2 a 35 anos). Apenas 28% dos pacientes foram capazes de instilar corretamente o colírio (instilação de 1 gota em saco conjuntival sem contato com a ponta do frasco). Contato da ponta do frasco com o olho ou tecido periocular ocorreu em 62% dos pacientes. Em 49% dos casos, o colírio caiu nas pálpebras ou fora do saco lacrimal na primeira tentativa. Duas ou mais gotas foram instiladas por 27% dos pacientes. Conclusão: A maioria dos pacientes com glaucoma é incapaz de instilar o colírio corretamente. A idade é um fator independente que influencia o desempenho da instilação de colírio.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Soluções Oftálmicas/administração & dosagem , Glaucoma/tratamento farmacológico , Fatores de Tempo , Instilação de Medicamentos , Acuidade Visual , Hipertensão Ocular/tratamento farmacológico , Educação de Pacientes como Assunto , Estudos Transversais , Fatores Etários , Cooperação do Paciente , Pressão Intraocular/efeitos dos fármacos